What does the temperature sensor do during the first 10 seconds before battery thermal runaway?
News

What does the temperature sensor do during the first 10 seconds before battery thermal runaway?

2026-11-03

bcaea8a0-16ff-4693-9889-c3f51a35fffc.png

GB 38031-2025 specifies the thermal event alarm requirement as "no later than 5 minutes after thermal runaway," but what truly determines whether those 5 minutes are meaningful are the final 10 seconds prior to thermal runaway. During these 10 seconds, the Temperature Sensor no longer measures temperature; instead, it measures the rate of temperature rise.

I. Why does the temperature curve before the deflagration appear flat?

Many temperature curves recorded by BMS systems are nearly straight lines immediately before the incident. The problem often lies not in inaccurate sensors, but in insufficient sampling frequency.

Thermal management channels typically sample data once every 1 second or even once every 10 seconds; a 10-second window therefore contains only 1 to 10 data points. During those 10 seconds, the temperature rise rate can jump from 0.5°C/min to 10°C/s—a difference of 1,200-fold. By the time you notice a "sharp rise" on the curve, the pressure relief valve has already opened.

II. What is happening inside the cell during the first 10 seconds?

The SEI film begins to decompose at 90–120 °C, while the separator melts at 130–180 °C; after extensive contact between the positive and negative electrodes, ohmic heating drives the heat generation rate to 10–100 °C/s. Taking a short circuit within a ternary cell as an example, the typical progression over these 10 seconds is as follows:

Table 1: Timeline during the first 10 seconds prior to thermal runaway (short-circuit condition inside an NCM cell)

time nodes

Internal state of the cell

surface temperature

rate of temperature rising

T-10s

Local melting of the diaphragm; minor internal short circuit

80~100℃

0.5~2℃/s

T-5s

Increase in internal short-circuit area

110~140℃

3~5℃/s

T-2s

Electrolyte decomposition, resulting in substantial gas generation

160~220℃

8~10℃/s

T-0

The pressure relief valve opens, triggering an eruption.

Above 300°C

>10℃/s

 

From T-10s to T-0, the temperature rose by only about 200 °C, yet the slope increased more than tenfold. At this stage, the most important parameter to monitor is dT/dt, not the absolute value.

III.Sampling interval: Determines how many points you can observe

With a 1-second sampling interval and a 10-second window containing 10 data points, it is barely possible to estimate the slope; with 10-second sampling, there is only 1 data point across the entire window, making it impossible to calculate the slope at all.

It is recommended that the thermal runaway warning channel operate at the 100 ms time scale; with 100 data points within the same window, dT/dt becomes truly diagnostically meaningful. GB 38031-2025 directly incorporates "a temperature rise rate reaching 1 °C/s" and "a voltage drop reaching 25% of the initial value" into the thermal runaway判定 criteria; this is precisely the underlying logic: relying solely on thresholds can lead to missed detections, whereas examining the rate of change enables reliable detection.

IV. Response Speed: Package thermal resistance is quietly eating away at your window

The sensor does not directly measure the cell temperature; rather, it measures the result after the cell temperature has been "filtered" through the package thermal resistance. Conventional stainless-steel probes have a thermal time constant ranging from several seconds to over ten seconds; by the time the probe has caught up, the 10-second window has already closed. Surface-mount NTC thermistors can achieve a thermal capacitance on the order of 0.02 J/K, enabling an overtemperature signal to be output within 150 ms; when mounted on the side of the cell, thin-film Pt1000 Thermistors can simultaneously provide a accuracy of ±0.1–0.2 °C and meet the requirements for a slim installation.

Table 2: Performance of the three temperature-measurement schemes within the first 10-second window

scheme

accuracy

response time

Number of points collectible within 10 seconds

Applicable locations

pasterNTC

±0.5~1℃

100~500ms

100

Large cell surface area, module interlayer

Thin-film Pt1000

±0.1~0.2℃

1~3s

100

Cell side and uniformity monitoring

Stainless steel PT100 probe

±0.15~0.3℃

5~15s

100 (reading lag)

Base of the terminal tabs and busbars

V. Site Selection: A Aspect More Prone to Being Overlooked Than Parameters

The sensor located at the center of the module measures the average temperature of a group of battery cells. The areas that actually heat up first are the tabs, the area surrounding the pressure relief valve, and the module interlayer. Place the probe at the base of the tab and the midpoint of the main surface, keep the measurement points within 50 mm of each other, and fill the gaps with thermal silicone; only then can you obtain the "local temperature" rather than the "average temperature" within the first 10 seconds. If the spacing is too large or the probe is not properly attached, even the highest level of accuracy will merely measure the temperature of the air.

VI. Three Common Misconceptions

  1. Only an absolute temperature threshold is set. An alarm at 60 °C will be triggered at a rate of 10 °C/s, reaching 300 °C in just 24 seconds.
  2. Temperature and voltage are not synchronized. During an internal short circuit, voltage sag typically occurs simultaneously with temperature rise; cross-validation using dual signals can suppress false alarms.
  3. Use thermal management channels for safety early warning. A one-second sampling interval is sufficient for temperature control, but not enough to save lives; therefore, the two channels should be designed separately.

Weilianfengran Sensing Technology (Shanghai) provides automotive-grade surface-mount NTCs, thin-film PT1000s, and dedicated thermocouple probes for busbar applications, which can be used in conjunction with a 100 ms sampling scheme to complete actual thermal response validation. If you require a battery thermal runaway early-warning solution, please contact us for technical documentation.