Product Knowledges

Product Knowledges

How many sensors do our quality inspectors "shoot out" every day?

How many sensors do our quality inspectors "shoot out" every day?

2026-11-05

Follow the quality inspector's checklist through the factory inspection of temperature sensors: handling 1,200 units per day and rejecting 30–40 units; how to evaluate four test stages—0 °C resistance, insulation resistance of 100 MΩ, 20 hot–cold cycles, and a 30 N tensile test.

view detail
What does the temperature sensor do during the first 10 seconds before battery thermal runaway?

What does the temperature sensor do during the first 10 seconds before battery thermal runaway?

2026-11-03

Within the 10 seconds prior to thermal runaway, the temperature rise rate can jump from 0.5°C/min to 10°C/s. This article analyzes three variables—sampling period, response speed, and sensor placement—to explain why dT/dt must be considered when providing a thermal runaway warning for batteries.

view detail
-50 °C to 600 °C: Understand the operating limits of seven types of sensors using a single temperature axis

-50 °C to 600 °C: Understand the operating limits of seven types of sensors using a single temperature axis

2026-10-29

 -50 °C to 600 °C temperature range—understand the operating limits of seven types of temperature sensors, including silicon-based ICs, NTCs, PT100s, and K/J/T thermocouples; compare their measurement ranges; and learn three key considerations for sensor selection to avoid common pitfalls.

view detail
PT100 wiring: two-wire, three-wire, and four-wire configurations have errors up to 10 times greater.

PT100 wiring: two-wire, three-wire, and four-wire configurations have errors up to 10 times greater.

2026-10-27

If your PT100 reading is high, do not replace the probe immediately. The errors associated with two-wire uncompensated connections, three-wire bridge compensation, and four-wire Kelvin connections differ by a factor of 10; this includes a comparison table for the three connection methods, examples of three common field connection errors, and a 30-second self-check method.

view detail
Is the multimeter unable to determine whether the sensor is functioning properly? Because you missed this step.

Is the multimeter unable to determine whether the sensor is functioning properly? Because you missed this step.

2026-10-20

Your multimeter shows normal resistance values for the PT100 sensor, but the readings remain inaccurate after reinstallation? This is likely due to the omission of the 500 V megohmmeter insulation resistance test. With our reference table for Class 3 hidden faults, a 4-step handheld multimeter testing procedure, and clear insulation judgment criteria, you can now master how to assess the performance of temperature sensors.

view detail
Why does the same PT100 sensor provide accurate readings in the morning but inaccurate ones in the afternoon?

Why does the same PT100 sensor provide accurate readings in the morning but inaccurate ones in the afternoon?

2026-10-15
"PT100 calibrated in the morning, but by the afternoon, a deviation appears" —this is one of the most common "unexplained" failures encountered by field instrumentation engineers. For the same PT100 sensor, with no change in measurement range, no...
view detail
Saved 80 yuan but lost 80,000 yuan: one probe ruined an entire batch of goods

Saved 80 yuan but lost 80,000 yuan: one probe ruined an entire batch of goods

2026-10-14

In Zhejiang Province, a coating and wiring plant incurred a loss of 980,000 yuan after 47 rolls of electrode sheets were scrapped due to drift in three uncertified K-type thermocouples. This article presents a comparison between uncertified and certified products, along with a checklist for identification and three critical criteria for probe selection.

view detail
How outrageous can it get when a sensor is installed backwards? 4 real-world field tests of misinstalled sensors

How outrageous can it get when a sensor is installed backwards? 4 real-world field tests of misinstalled sensors

2026-10-09

How disastrous can it be when a temperature sensor is installed backwards? Four real-world scenarios: thermocouple reversed connection leading to-50 °C readings; compensation leads reversed connection preventing furnace temperature rise; differential pressure transmitter H/L reversed connection causing negative flow readings; wall-mounted sensor installed backwards resulting in inaccurate data. Reference lookup tables included.

view detail
How to Select Temperature Sensor Sleeves Made of Stainless Steel, Ceramic, or Glass

How to Select Temperature Sensor Sleeves Made of Stainless Steel, Ceramic, or Glass

2026-09-24

How to select protective sleeves for stainless steel, ceramic, and glass temperature sensors? A comparison table covering temperature resistance range, corrosion resistance, and thermal shock resistance, along with three key selection criteria and three common pitfalls to avoid—ensuring you make the right choice once and avoid unnecessary expenses.

view detail
Three Hidden Costs in Temperature Monitoring at Heat Exchange Stations During the 2026 Heating Season

Three Hidden Costs in Temperature Monitoring at Heat Exchange Stations During the 2026 Heating Season

2026-09-22

Three hidden costs in temperature measurement at heat exchange stations: deviations in heat settlement calculations, inaccurate water supply temperature control, and frequent replacement of temperature probes. Includes a precision comparison and installation verification checklist for paired temperature sensors.

Recommended URL: /huanrezhan-ceming-3yinxiang-chengben

view detail